2026 - 1 Issue

Review

Quantifying Gaze Tracking for Visual Field Reliability Estimation. A Systematic Review

Full Text links

Summary

Aims: This systematic review aimed to investigate whether quantitative metrics derived from gaze tracking (GT) outputs during visual field (VF) testing with an automated perimeter could enhance the evaluation of test reliability.

Materials and Methods: A systematic search of PubMed, Cochrane, LILACS, and IBECS databases, from inception to August 31, 2024, was conducted.

Results: Eight studies – four cross-sectional and four cohort – met the inclusion criteria, comprising 8,181 visual field tests from 3,687 patients. The studies were categorized based on testing strategy: SITA Standard, Fast, and Faster. In the SITA Standard group, GT parameters were associated with visual field result reproducibility and the structure-function relationship in glaucoma, but were influenced by ocular surface variables. In the SITA Fast and Faster group, results were mixed: some studies suggested GT metrics could complement conventional reliability parameters, while others concluded that GT quantitative metrics did not offer clinically meaningful insights beyond existing methods.

Conclusion: GT trace quantification shows promise as an objective reliability parameter for VF testing, particularly within the SITA Standard framework. Advanced image analysis techniques, including artificial intelligence, could facilitate automated GT parameter quantification, streamlining processes and supporting further studies to evaluate their impact on VF data reliability and clinical decision-making.

References

  1. Tham YC, Li X, Wong TY, Quigley HA, Aung T, Cheng CY. Global Prevalence of Glaucoma and Projections of Glaucoma Burden through 2040. Ophthalmology. 2014;121(11):2081-2090.
  2. Lee SSY, Mackey DA. Glaucoma – risk factors and current challenges in the diagnosis of a leading cause of visual impairment. Maturitas. 2022;163:15-22.
  3. Saifi AI, Nagrale P, Ansari KK, Saifi I, Chaurasia S. Advancement in Understanding Glaucoma: A Comprehensive Review. Cureus. 2023;15(9):e46254.
  4. Ishiyama Y, Murata H, Asaoka R. The Usefulness of Gaze Tracking as an Index of Visual Field Reliability in Glaucoma Patients. Invest Ophthalmol Vis Sci. 2015;56(11):6233-6236.
  5. Ishiyama Y, Murata H, Mayama C, Asaoka R. An Objective Evaluation of Gaze Tracking in Humphrey Perimetry and the Relation with the Reproducibility of Visual Fields: A Pilot Study in Glaucoma. Invest Ophthalmol Vis Sci. 2014;55(12):8149-8152.
  6. Heijl A, Patella VM, Bengtsson B. The Field Analyzer Primer: Excellent Perimetry. 5th ed. Jena: Carl Zeiss Meditec; 2021. p. 22–27, 43- 45, 90–94.
  7. Ishiyama Y, Murata H, Hirasawa H, Asaoka R. Estimating the Usefulness of Humphrey Perimetry Gaze Tracking for Evaluating Structure–Function Relationship in Glaucoma. Invest Ophthalmol Vis Sci. 2015;56(13):7801-7805.
  8. Arai T, Murata H, Matsuura M, Usui T, Asaoka R. The association between ocular surface measurements with visual field reliability indices and gaze tracking results in preperimetric glaucoma. Br J Ophthalmol. 2018;102(4):525-530.
  9. Asaoka R, Fujino Y, Aoki S, Matsuura M, Murata H. Estimating the Reliability of Glaucomatous Visual Field for the Accurate Assessment of Progression Using the Gaze-Tracking and Reliability Indices. Ophthalmology Glaucoma. 2019;2(2):111-119.
  10. Camp AS, Long CP, Galor A, Yamane M, Proudfoot JA, Weinreb RN. Dry Eye Symptom Severity and Visual Field Reliability Metrics. Journal of Glaucoma. 2022;31(5):305-309.
  11. Page MJ, McKenzie JE, Bossuyt PM, et al. The PRISMA 2020 statement: an updated guideline for reporting systematic reviews. BMJ. 2021; 372:n71.
  12. Bengtsson B, Heijl A. SITA Fast, a new rapid perimetric threshold test. Description of methods and evaluation in patients with manifest and suspect glaucoma. Acta Ophthalmol Scand. 1998;76(4):431-437.
  13. Camp AS, Long CP, Patella VM, Proudfoot JA, Weinreb RN. Standard Reliability and Gaze Tracking Metrics in Glaucoma and Glaucoma Suspects. Am J Ophthalmol. 2022;234:91-98.
  14. Phu J, Kalloniatis M. Gaze tracker parameters have little association with visual field metrics of intrasession frontloaded SITA‐FASTER 24–2 visual field results. Ophthalmic Physiologic Optic. 2022;42(5):973-985.