<?xml version="1.0" encoding="UTF-8"?>
<article article-type="research-article" dtd-version="1.3" xml:lang="en">
  <front>
    <journal-meta>
      <journal-title-group>
        <journal-title>Czech and Slovak Ophthalmology</journal-title>
      </journal-title-group>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="publisher-id">227</article-id>
      <article-id pub-id-type="doi">10.31348/2022/2</article-id>
      <article-categories>
        <subj-group>
          <subject>Review</subject>
        </subj-group>
      </article-categories>
      <title-group>
        <article-title>Intraoperative Optical Coherence Tomography –Available Technologies and Possibilities of Use. A Review</article-title>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author">
          <name>
            <surname>Benda</surname>
            <given-names>Tomáš</given-names>
          </name>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Studený</surname>
            <given-names>Pavel</given-names>
          </name>
          <contrib-id contrib-id-type="orcid">https://orcid.org/0000-0003-1279-4074</contrib-id>
        </contrib>
      </contrib-group>
      <pub-date date-type="pub" publication-format="electronic">
        <day>28</day>
        <month>1</month>
        <year>2022</year>
      </pub-date>
      <issue>6</issue>
      <elocation-id>1</elocation-id>
      <abstract>
        <p>Optical coherence tomography (OCT) is a non-contact and non-invasive imaging and diagnostic method, that allows the imaging of ocular tissues on transverse sections in extremely high quality of micrometer resolution. The physical principle of OCT is analogous to ultrasound, but it uses infrared radiation instead of acoustic waves. By using a low coherent radiation source, it is possible to achieve a higher resolution. Based on the obtained data, the computer can reconstruct two or three-dimensional images of the examined tissue. In recent years, we have seen a rapid development in ophthalmic surgery, especially in surgical instruments and imaging methods. However, the technology of surgical microscopes does not change significantly and thus becomes a limiting factor in the development of ophthalmic microsurgery. The integration of the OCT into surgical microscopes, so the introduction of the Intraoperative Optical Coherence Tomography (iOCT), opens up further possibilities for displaying/looking at the operating field and adapting surgical techniques to the current situation during the surgery. On the contrary, the disadvantage is the prolongation of the surgery time and thus the theoretical increase in possible complications related to the surgery. iOCT can be used for operations on the anterior and posterior segment of the eye. In anterior segment surgery, it is used mostly in penetrating and lamellar keratoplasty, glaucoma surgery and cataract surgery. In posterior segment surgery, it is used during pars plana vitrectomy. The aim of the article is to provide a comprehensive overview of the current possibilities of using iOCT in eye surgery.</p>
      </abstract>
      <kwd-group>
        <kwd>intraoperative OCT</kwd>
      </kwd-group>
    </article-meta>
  </front>
  <back>
    <ref-list>
      <title>References</title>
      <ref id="R4566">
        <mixed-citation>Gulkas S, Cekic O. Intraoperative Optical Coherence Tomography, Novel Diagnostic Methods in Ophthalmology, IntechOpen. 2019.</mixed-citation>
      </ref>
      <ref id="R4567">
        <mixed-citation>Ehlers JP, Dupps WJ, Kaiser PK, et al. The prospective intraoperative and perioperative ophthalmic Imaging with optical coherence tomography (PIONEER) study: 2-year results. American Journal of Ophthalmology. 2014;158:999-1007.</mixed-citation>
      </ref>
      <ref id="R4568">
        <mixed-citation>Ehlers JP, Goshe J, Dupps WJ, et al. Determination of feasibility and utility of microscope-integrated optical coherence tomography during ophthalmic surgery: The DISCOVER study RESCAN results. JAMA Ophthalmology. 2015;133:1124-1132.</mixed-citation>
      </ref>
      <ref id="R4569">
        <mixed-citation>Steven P, Le Blanc C, Velten K, et al. Optimizing descemet membrane endothelial keratoplasty using intraoperative optical coherence tomography. JAMA Ophthalmology. 2013;131:1135-1142.</mixed-citation>
      </ref>
      <ref id="R4570">
        <mixed-citation>Ehlers JP, Modi YS, Pecen PE, et al. The DISCOVER study 3-year results: Feasibility and usefulness of microscope-integrated intraoperative OCT during ophthalmic surgery. Ophthalmology. 2018;125:1014-1027.</mixed-citation>
      </ref>
      <ref id="R4571">
        <mixed-citation>El-Haddad MT, Tao YK. Automated stereo vision instrument tracking for intraoperative OCT guided anterior segment ophthalmic surgical maneuvers. Biomedical Optics Express. 2015;6:3014- 3031.</mixed-citation>
      </ref>
      <ref id="R4572">
        <mixed-citation>Eguchi H, Kusaka S, Arimura-Koike E, et al. Intraoperative optical coherence tomography (RESCAN((R)) (700) for detecting iris incarceration and iridocorneal adhesion during keratoplasty. International Ophthalmology. 2017;37:761-765.</mixed-citation>
      </ref>
      <ref id="R4573">
        <mixed-citation>Titiyal JS, Kaur M, Falera R. Intraoperative optical coherence tomography in anterior segment surgeries. Indian Journal of Ophthalmology. 2017;65:116-121.</mixed-citation>
      </ref>
      <ref id="R4574">
        <mixed-citation>Au J, Goshe J, Dupps WJ Jr, Srivastava SK, Ehlers JP. Intraoperative optical coherence tomography for enhanced depth visualization in deep anterior lamellar keratoplasty from the PIONEER study. Cornea. 2015;34:1039-1043.</mixed-citation>
      </ref>
      <ref id="R4575">
        <mixed-citation>Steven P, Le Blanc C, Lankenau E, et al. Optimising deep anterior lamellar keratoplasty (DALK) using intraoperative online optical coherence tomography (iOCT). The British Journal of Ophthalmology. 2014;98:900-904.</mixed-citation>
      </ref>
      <ref id="R4576">
        <mixed-citation>Kobayashi A, Yokogawa H, Mori N, Sugyiama K. Visualization of precut DSAEK and pre-stripped DMEK donor corneas by intraoperative optical coherence tomography using the RESCAN 700. BMC Ophthalmology. 2016;16:135.</mixed-citation>
      </ref>
      <ref id="R4577">
        <mixed-citation>Saad A, Guilbert E, Grise-Dulac A, Sabatier P, Gatinel D. Intraoperative OCT-assisted DMEK: 14 consecutive cases. Cornea. 2015;34:802-807.</mixed-citation>
      </ref>
      <ref id="R4578">
        <mixed-citation>Kumar RS, Jariwala MU, Sathidevi AV, et al. A pilot study on feasibility and effectiveness of intraoperative spectral-domain optical coherence tomography in glaucoma procedures. Transl Vis Sci Technol 2015;4:2:2.</mixed-citation>
      </ref>
      <ref id="R4579">
        <mixed-citation>Hirnschall N, Amir-Asgari S, Maedel S, Findl O. Predicting the postoperative intraocular lens position using continuous intraoperative optical coherence tomography measurements. Investigative Ophthalmology &amp; Visual Science. 2013;54:5196-5203.</mixed-citation>
      </ref>
      <ref id="R4580">
        <mixed-citation>Das S, Kummelil MK, Kharbanda V, et al. Microscope integrated intraoperative spectral domain optical coherence tomography for cataract surgery: Uses and applications. Current Eye Research. 2016;41:643-652.</mixed-citation>
      </ref>
      <ref id="R4581">
        <mixed-citation>Almutlak MA, Aloniazan T, May W. Real-time optical coherence tomography incorporated in the operating microscope during cataract surgery. Middle East African Journal of Ophthalmology. 2017;24:156-158.</mixed-citation>
      </ref>
      <ref id="R4582">
        <mixed-citation>Ruland K, Bouldin TW, Davis RM, Fleischman D. Intraoperative optical coherence tomography-assisted retrocorneal fibrous membrane biopsy and excision. American Journal of Ophthalmology Case Reports. 2018;11:101-104.</mixed-citation>
      </ref>
      <ref id="R4583">
        <mixed-citation>Siebelmann S, Horstmann J, Scholz P, et al. Intraoperative changes in corneal structure during excimer laser phototherapeutic keratectomy (PTK) assessed by intraoperative optical coherence tomography. Graefe’s Archive for Clinical and Experimental Ophthalmology. 2018;256:575-581.</mixed-citation>
      </ref>
      <ref id="R4584">
        <mixed-citation>Němec P, Kousal B, Löfflerová B. Optická koherenční tomografie-Klinický atlas sítnicových patologií. 2. vydání. Praha: Mladá fronta; 2017. 405.</mixed-citation>
      </ref>
      <ref id="R4585">
        <mixed-citation>Hahn P, Migacz J, O’Connell R, Maldonado RS, Izatt JA, Toth CA. The Use of Optical Coherence Tomography in Intraoperative Ophthalmic Imaging. Ophthalmic Surg Lasers Imaging. 2011 Jul; 42(0): S85-S94.</mixed-citation>
      </ref>
      <ref id="R4586">
        <mixed-citation>Ray R, Barañano DE, Fortun JA, et al. Intraoperative microscope- -mounted spectral domain optical coherence tomography for evaluation of retinal anatomy during macular surgery. Ophthalmology. 2011;118(11):2212-2217.</mixed-citation>
      </ref>
      <ref id="R4587">
        <mixed-citation>Binder S, Falkner-Radler CI, Hauger C, Matz H, Glittenberg C. Feasibility of intrasurgical spectral-domain optical coherence tomography. Retina. 2011;31(7):1332-1336.</mixed-citation>
      </ref>
      <ref id="R4588">
        <mixed-citation>Ehlers JP, Tao YK, Farsiu S, Maldonado R, Izatt JA, Toth CA. Visualization of real-time intraoperative maneuvers with a microscope- -mounted spectral domain optical coherence tomography system. Retina. 2013;33(1):232-236.</mixed-citation>
      </ref>
      <ref id="R4589">
        <mixed-citation>Schechet SA, Komati R, Blair MP, Hariprasad SM. Update on Intraoperative OCT for Vitreoretinal Surgery, Retinal Physician, Volume: 17, Issue: Jan/Feb 2020, page(s): 34-36, 39, 40.</mixed-citation>
      </ref>
      <ref id="R4590">
        <mixed-citation>Ehlers JP, Itoh Y, Xu LT, Kaiser PK, Singh RP, Srivastava SK. Factors associated with persistent subfoveal fluid and complete macular hole closure in the PIONEER study. Invest Ophthalmol Vis Sci. 2014;56(2):1141-1146.</mixed-citation>
      </ref>
      <ref id="R4591">
        <mixed-citation>Ehlers JP, Kaiser PK, Srivastava SK. Intraoperative optical coherence tomography using the RESCAN 700: Preliminary results from the DISCOVER study. The British Journal of Ophthalmology. 2014;98:1329-1332.</mixed-citation>
      </ref>
      <ref id="R4592">
        <mixed-citation>Runkle A, Srivastava SK, Ehlers JP. Microscope-integrated OCT feasibility and utility with the EnFocus system in the DISCOVER study. Ophthalmic Surg Lasers Imaging Retina. 2017;48(3):216- 222.</mixed-citation>
      </ref>
      <ref id="R4593">
        <mixed-citation>Ehlers JP, Kaiser PK, Srivastava SK. Intraoperative optical coherence tomography using the RESCAN 700: Preliminary results from the DISCOVER study. Br J Ophthalmol. 2014;98(10):1329-1332.</mixed-citation>
      </ref>
      <ref id="R4594">
        <mixed-citation>Ehlers JP, Goshe J, Dupps WJ, et al. Determination of feasibility and utility of microscope-integrated optical coherence tomography during ophthalmic surgery: the DISCOVER study RESCAN results. JAMA Ophthalmol. 2015;133(10):1124-1132.</mixed-citation>
      </ref>
      <ref id="R4595">
        <mixed-citation>Stuart A, Ehlers JP, Lauer AK, MacLaren RE. Intraoperative OCT: An Emerging Technology. EyeNet Magazine August 2018.</mixed-citation>
      </ref>
      <ref id="R4596">
        <mixed-citation>Fram NR, Masket S, Wang L. Comparison of intraoperative aberrometry, OCT-based IOL formula, Haigis-l, and Masket formulae for IOL power calculation after laser vision correction. Ophthalmology 2015;122:6:1096-1101.</mixed-citation>
      </ref>
      <ref id="R4597">
        <mixed-citation>Ehlers JP, Tam T, Kaiser PK, Martin DF, Smith GM, Srivastava SK. Utility of intraoperative optical coherence tomography during vitrectomy surgery for vitreomacular traction syndrome. Retina. 2014;34(7):1341-1346.</mixed-citation>
      </ref>
      <ref id="R4598">
        <mixed-citation>Ehlers JP, Xu D, Kaiser PK, Singh RP, Srivastava SK. Intrasurgical dynamics of macular hole surgery: an assessment of surgery-induced ultrastructural alterations with intraoperative optical coherence tomography. Retina. 2014;34(2):213-221.</mixed-citation>
      </ref>
    </ref-list>
  </back>
</article>
