<?xml version="1.0" encoding="UTF-8"?>
<article article-type="research-article" dtd-version="1.3" xml:lang="en">
  <front>
    <journal-meta>
      <journal-title-group>
        <journal-title>Czech and Slovak Ophthalmology</journal-title>
      </journal-title-group>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="publisher-id">112</article-id>
      <article-id pub-id-type="doi">10.31348/2019/2/2</article-id>
      <article-categories>
        <subj-group>
          <subject>Original article</subject>
        </subj-group>
      </article-categories>
      <title-group>
        <article-title>Correction of Myopia and Myopic Astigmatism by Femtosecond Laser in Situ Keratomileusis</article-title>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author">
          <name>
            <surname>Řeháková</surname>
            <given-names>Tereza</given-names>
          </name>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Veliká</surname>
            <given-names>Věra</given-names>
          </name>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Jirásková</surname>
            <given-names>Naďa</given-names>
          </name>
        </contrib>
      </contrib-group>
      <pub-date date-type="pub" publication-format="electronic">
        <day>20</day>
        <month>7</month>
        <year>2019</year>
      </pub-date>
      <issue>2</issue>
      <elocation-id>2</elocation-id>
      <abstract>
        <p>Aim: We analysed one-year refractive results and the incidence of complications in patients with correction of low-to-high myopia or myopic astigmatism by femtosecond laser in situ keratomileusis (FS-LASIK) using femtosecond laser LenSx® (Alcon, Fort Worth, Texas, USA) a excimer laser Excimer Amaris 500 (Schwind eye-tech-solutions GmbH and Co KG, Kleinostheim, Germany). Methods: To the retrospective study were included 171 eyes of 87 patients (38 men, 49 women) who underwent correction of myopia and myopic astigmatism by FS-LASIK in the outpatient Department of Ophthalmology, University Hospital in Hradec Králové between 2013-2017. We assessed uncorrected visual acuity (UCVA) and best corrected visual acuity (BCVA), subjective refraction, central corneal thickness (CCT) in the thinnest point, patient’s satisfaction and the incidence of complications in the one-year follow-up period. Results: At the time of laser procedure the mean patient‘s age was 29,26 ± 6,47 years (range 18 to 46 years). In 21 eyes was corrected myopia (range -6,5 to -2,5 D sph) and in 150 eyes myopic astigmatism (range -8,75 to -0,25 D sph and -3,0 to -0,25 D cyl). The mean preoperative UCVA 0,06 ± 0,08 (range 0,02 to 0,8) got better to 1,12 ± 0,17 (range 0,8 to 1,5) at the end of follow-up period. There wasn’t statistically significant change in BCVA between preoperative and postoperative values. Preoperative mean value of subjective refraction was -4,14 ± 1,43 D sph (range -8,5 to -1 D sph) and -0,57 ± 0,58 D cyl (range -3 to 0 D cyl) and after 12 months -0,02 ± 0,16 D sph (range -0,1 to 0,75 D sph) and -0,01 ± 0,1 D cyl (range -0,5 to 0,5 D cyl). The initial mean CCT was 554,76 ± 30,07 μm (range 485 to 660 μm), after 6 months 494,06 ± 34,99 μm (range 421 to 594 μm) and after 12 months 492,92 ± 34,55 μm (range 411 to 592 μm). We observed peroperative complications in 3 eyes. The suction loss of femtosecond laser occurred during flap creation due to sudden eye movement. Postoperatively in one case we enrolled flap pucker first postoperative day. In other case flap dislocation occurred after abdonimal surgery under general anesthesia which was performed 3 months after refractive procedure and we had to indicate flap reposition. The mean grade of patient’s satisfaction was at the end of follow-up period 1,04. The most often complaints were the sensation of dry eye (10 patients) and blurry vision during computer working, inadequate lighting and fatique (6 pacients). Conclusions: According to our experience correction of low-to-high myopia or myopic astigmatism by using FS-LASIK is an effective, relatively safe and predictable method. The basic assumption of good postoperative results and patient’s satisfaction is thorough and comprehensive preoperative examination with respect to indication criteria.</p>
      </abstract>
      <kwd-group>
        <kwd>myopia</kwd>
        <kwd>laser in situ keratomileusis</kwd>
        <kwd>femtosecond assisted LASIK</kwd>
        <kwd>refractive surgery</kwd>
      </kwd-group>
    </article-meta>
  </front>
  <back>
    <ref-list>
      <title>References</title>
      <ref id="R6703">
        <mixed-citation>Al Arfaj, K., Hantera, M.M.: Comparison of LASEK, mechanical microkeratome LASIK and Femtosecond LASIK in low and moderate myopia. Saudi J of Ophthalmol., 28 (3); 2014: 214-219.</mixed-citation>
      </ref>
      <ref id="R6704">
        <mixed-citation>Arbelaez, M.C., Mosquera, S.A.: The SWIND AMARIS Total- Tech Laser as An All-Rounder in Refractive Surgery. Modele East Afr J Ophthalmol. 16 (1); 2009: 46-53.</mixed-citation>
      </ref>
      <ref id="R6705">
        <mixed-citation>Cosar, C.B., Gonen, T., Moray, M. et al.: Comparision of visual acuity, refractive results and complications of femtosecond laser with mechanical microkeratome in LASIK. Inj J Ophthalmol. 6c(3); 2013: 350-355.</mixed-citation>
      </ref>
      <ref id="R6706">
        <mixed-citation>Espandar, L., Meyer, J.: Intraoperative and Postoperative Complications of Laser in situ Keratomileusis Flap Creation Using IntraLase Femtosecond Laser and Mechanical Microkeratomes. Middle East Afr J Ophathalmol. 17 (1); 2010: 56-59.</mixed-citation>
      </ref>
      <ref id="R6707">
        <mixed-citation>Foster, P.J., Jiang, Y.: Epidemiology of myopia. Eye. 28 (2); 2014: 202-8.</mixed-citation>
      </ref>
      <ref id="R6708">
        <mixed-citation>Hashemi, H., Fotouhi, A., Yekta, A. et al.: Global and regional estimates of prevalence of refractive errors: Systematic review and meta-analysis. J Curr Ophathalmol. 30 (1); 2018: 3-22.</mixed-citation>
      </ref>
      <ref id="R6709">
        <mixed-citation>Hashmani, S., Hashmani, N., Rajani, H. et al.: Comparision of visual acuity, refractive outcomes, and satisfactory between LASIK performed with a microkeratome and femto laser. Clin Ophthalmol. 11; 2017: 1009-1014.</mixed-citation>
      </ref>
      <ref id="R6710">
        <mixed-citation>Heissigerová, J. et al.: Oftalmologie. Praha, Maxdorf, 2018, 61-67s.</mixed-citation>
      </ref>
      <ref id="R6711">
        <mixed-citation>Kanellopoulos A.J., Asimellis, G.: Long-term bladeless LASIK outcomes with the FS200 Femtosecond and EX500 Excimer Laser workstation: the Refractive Suite. Clin Ophthalmol, 7; 2013: 261-269.</mixed-citation>
      </ref>
      <ref id="R6712">
        <mixed-citation>Kuchynka, P. et al.: Oční lékařství. Praha, Grada Publishing, 2016, 222-234s.</mixed-citation>
      </ref>
      <ref id="R6713">
        <mixed-citation>Niparugs, M., Tananuvat, N., Chaidaroon, W. et al.: Outcomes of LASIK for Myopia and Myopic Astigmatism Correction with the FS200 Femtosecond Laser and EX500 Excimer Laser Platform. Open Ophthalmol J, 12; 2018: 63-71.</mixed-citation>
      </ref>
      <ref id="R6714">
        <mixed-citation>Pajic, B., Vastardis, I., Eggspuehler, B. et al.: Femtosecond laser versus mechanical microkeratome-assisted flap creation for LASIK: a prospective, randomized, paired-eye study. Clin Ophthalmol, 8; 2014: 1883-1889.</mixed-citation>
      </ref>
      <ref id="R6715">
        <mixed-citation>Piao, J., Li, Y.J., Whang, W.J. et al.: Comparative evaluation of visual outcomes and corneal asphericity after laser-assisted in situ keratomileusis with the six-dimension Amaris excimer laser system. PloS One. 12 (2); 2017: e0171851.</mixed-citation>
      </ref>
      <ref id="R6716">
        <mixed-citation>Pietila, J., Huhtala, A., Makinen, P. et al.: Flap characteristics, predictability, and safety of the Ziemer FEMTO LDV femtosecond laser with the disposable suction ring for LASIK. Eye (Lond). 28 (1); 2014: 66-71.</mixed-citation>
      </ref>
      <ref id="R6717">
        <mixed-citation>Pietila, J., Huhtala, A., Makinen, P. et al.: Laser-assisted in situ keratomileusis flap creation with the three-dimensional, transportable Ziemer FEMTO LDV model Z6 I femtosecond laser. Acta Ophthalmol. 92 (7); 2014: 650-655.</mixed-citation>
      </ref>
      <ref id="R6718">
        <mixed-citation>Pokroy, R., Mimouni, M., Sela, T.: Myopic laser in situ keratomileusis retreatment: Incidence and associations. J Cataract Refract Surg. 42 (10); 2016: 1408-1414.</mixed-citation>
      </ref>
      <ref id="R6719">
        <mixed-citation>Rozskowska, A.M., Mosquera, S.A.: Use of the Femtosecond Lasers in Ophthalmology. The European Physical Journal Conferences 167 [Internet], Dostupné z https://doi. org/10.1051/epjconf/201816705004.<pub-id pub-id-type="doi">10.1051/epjconf/201816705004</pub-id></mixed-citation>
      </ref>
      <ref id="R6720">
        <mixed-citation>Tabacaru, B., Stanca, H.T.: One year refractive outcomes of Femtosecond LASIK in mild, moderate and high myopia. Rom J Ophthalmol, 61 (1); 2017: 23-31.</mixed-citation>
      </ref>
      <ref id="R6721">
        <mixed-citation>Williams, K.M., Verhoeven, V.J., Cumberland, P. et al.: Prevalence of refractive error in Europe: the European Eye Epidemiology Consortium. Eur J Epidemiol. 30 (4); 2015: 305-15.</mixed-citation>
      </ref>
    </ref-list>
  </back>
</article>